Soft Foundation Treatment 300g Polyester PP Long Fiber Geotextile Price for Engineering Biogas
Subclassification:
Geotextile
Key words:
Geotextile
Email:
WhatsApp:
Product Details
| Product specification |
| Name; Non-woven geotextiles |
| Thickness; 100g-1300g |
| Length; 1-6 meters, if there is a unique measurement can be customized |
| Color; White, black, orange, aid customized hues |
Polyester Filament Needle-Punched Geotextile is a high-performance nonwoven fabric designed for a wide range of geotechnical applications, including separation, filtration, reinforcement, protection, and drainage. This geotextile is commonly used to separate different soil layers, such as clay and drainage systems, and to protect liners from potential damage.
Material and Manufacturing Process:
Our Polyester Filament Needle-Punched Geotextile is manufactured from 100% virgin polyester chips. Using advanced spunbond technology, continuous polyester filaments are extruded directly from the chips, creating a strong and durable fabric. The filaments are then needle-punched to form a stable three-dimensional structure, ensuring higher tensile strength and superior performance.

For Filtration:
When water passes from a fine-grained to a coarse grained layer, Non woven Geotextile can maintain best particles well. For an example, when water flows from a sandy soil into a Geotextile wrapped gravel drain.
For Separation:
It can separate two layers of soil with special bodily properties. For an eample, the separation of street gravel from smooth sub-base materials.
For Drainage:
It can drain liquid or gasoline from the airplane of the fabric, which leads to draining or venting of the soil. For an example, the fuel vent layer in a landfill cap.
For Reinforcement:
It can enhance the load bearing ability of a precise soil structure. For an example, the reinforcement of a keeping wall.
Properties | Test Method | Unit | GXSF150 | GXSF200 | GXSF300 | GXSF400 | GXSF500 | GXSF600 | GXSF800 | GXSF1000 |
Tensile Strength(MD/TD) | ASTM D4595 | kN/m | 8 | 11 | 20 | 24 | 28 | 34 | 48 | 50 |
Tensile Elongation(MD/TD) | ASTM D4595 | % | 50 | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
Grab Tensile Strength(MD/TD) | ASTM D4632 | N | 520 | 700 | 1100 | 1500 | 1800 | 2200 | 2800 | 3000 |
Grab Elongation(MD/TD) | ASTM D4632 | % | 50 | 50 | 60 | 60 | 60 | 60 | 60 | 60 |
Trapezoidal Tear Strength(MD/TD) | ASTM D4533 | N | 220 | 330 | 400 | 480 | 560 | 620 | 860 | 880 |
CBR Burst Strength | ASTM D6241 | N | 1700 | 2400 | 3200 | 4300 | 5300 | 6000 | 6800 | 7000 |
Pore Size O90 | ASTM D4751 | µm | 90 | 85 | 80 | 75 | 70 | 60 | 55 | 50 |
Water Flow Q100 | ASTM D4491 | L/m2/s | 160 | 145 | 140 | 120 | 105 | 95 | 90 | 80 |
Weight | ASTM D5261 | g/m2 | 150 | 200 | 300 | 400 | 500 | 600 | 800 | 1000 |
![]() | ![]() | ![]() | ![]() | ![]() |